Aerospace, Rail & Transportation

Specific Test List

European Railway EN 45545-2 (2013+A1:2015)
(Other Than Wire & Cable)Download PDFDownload

Test Sample Size Performance Time
ISO 5658-2 (Lift)
R1, R2, R3, R4, R7, R11, R12, R17
4 pieces md: 150 mm x 800 mm
4 pieces cmd: 150 mm x 800 mm
7 - 10 days
EN ISO 5659-2 (Smoke Density)
25 kW Exposure with pilot flame:
R5, R8, R9, R10, R20, R21, R22 & R23
6 pieces: 75 mm x 75 mm x 25 mm MT 7 - 10 days
50 kW Exposure without pilot flame:
R1, R2, R3, R6, R7, R11, R12, R17
6 pieces: 75 mm x 75 mm x 25 mm MT 7 - 10 days
ISO 5660-1 (Cone Calorimeter)
25 kW Exposure:
R5, R8, R9, R10, R19, R20, R21
6 pieces: 100 mm x 100 mm x 50 mm MT 7 - 10 days
50 kW Exposure:
R1, R2, R3, R6, R7, R11, R12, R17
6 pieces: 100 mm x 100 mm x 50 mm MT 7 - 10 days
EN ISO 9239-1 (Flooring Radiant Panel)
R8, R10
4 pieces md: 230 mm x 1050 mm
4 pieces cmd: 230 mm x 1050 mm
7 - 10 days
EN ISO 11925-2 (Single Flame)
R4, R5
8 pieces md: 90 mm x 250 mm
8 pieces cmd: 90 mm x 250 mm
7 - 10 days
Combustion Toxicity, Annex C,
Method 1: Smoke Chamber
25 kW Exposure with pilot flame:
R5, R8, R9, R10, R20, R21
16 pieces: 75 mm x 75 mm x 25 mm MT 25 - 30 days
50 kW Exposure without pilot flame:
R1, R2, R3, R4, R6, R7, R11, R12, R17
16 pieces: 75 mm x 75 mm x 25 mm MT 25 - 30 days
EN ISO 1182 (Noncombustibility)
R Set N/A
20 pieces: 38 mm x 38 mm x 50 mm 10 - 14 days
ISO/TR 9705-2 (Corner Fire Test)
R18
Available upon request  
EN ISO 12952-2 (Match Flame)
R20
2 actual bedding items
(blankets, pillows, etc)

NOTE: Mattresses are tested by ISO 5660-1 & 5659-2
7 - 10 days
EN ISO 4589-2 (Oxygen Index)
R22, R23, R24
Available upon request 10 - 14 days

cmd = Cross machine direction

md = Machine direction

MT = Maximum thickness

N/A = Not applicable